| Capacity (VA) |
1000 |
2000 |
3000 |
| Rated Power(W) |
850 |
1700 |
2550 |
| AC Input |
Voltage |
220V Single Phase (L-N-PE) /110V Single Phase (L-N-PE) |
Voltage range |
Low limit 140V¡À5, upper limit 300V¡À5 (Low limit 120V¡À5 optional for full load)/ Low limit 85V¡À5, upper limit 135V¡À5 |
Frequency |
50Hz ¡À 10% (45~55Hz)/60Hz ¡À 10% (54~66Hz) |
Power Factor |
>0.98 |
| AC Output |
Voltage |
Single Phase 220V ¡À1% / 110V ¡À1% |
Frequency |
50Hz ¡À 0.3% (49.85~50.15Hz) /60Hz ¡À 0.3% (59.82~60.18Hz) |
Wave |
Pure Sine Wave, distortion<3% (linearity full load) |
| Transfer Time |
Recover mains 0ms, by pass invert ¡Ü4ms |
| Battery |
Voltage |
36V |
72V/96V OPTIONAL |
96V |
Quantity |
3x12V 7Ah |
External 3pcs |
6/8x12V 7Ah |
External 6/8pcs |
8x12V 7Ah |
External 8pcs |
Max Charging Current |
8.5A |
10A/8A |
8A |
Mode of Charging |
Constant charging (User can select Constant and float charge automatic switch) |
Time detect |
As per user's setting period |
| Alarm |
Mains off |
Beeping sound every 4seconds; 90s later stop |
Battery off |
Beeping sound every 1 second |
Overload |
Overload indicator shine, beeping a long time |
UPS Abnormity |
Fail indicator shine, beeping a long time |
| Protection |
Battery |
Battery voltage low, automatic shut down |
Overload |
105% working 1minture, >125% shut off, Auto recover after load back normal |
Overheat |
Inverter temperature >90oC, automatically switch to by pass |
Output short circuit |
Limit current, automatically shut down, cut fuse & breakers off |
UPS Abnormity |
Automatically switch to by pass or automatically shut down |
By pass |
Mains voltage beyond 250V, UPS cannot switch to by pass |
Telephone |
OPTIONAL, RJ11 & RJ45 (Customer should ask sperately when place the order) |
| Indication |
LED display |
Mains, by pass output, battery output, battery lack voltage, battery level,overload, failure alarm |
LCD display |
UPS status, input/output voltage, input frequency, battery voltage, battery ca |
History |
Mains abnormity-normal, Mains normal-abnormity, Output abnormity, over |
| Modification of Fan |
Loading capacity<35% low speed running,Loading capacity >35%,high speed running |
| UPS efficiency |
85% (full resistant load) |
| Communication interface |
RS232: UPS status, input voltage/frequency, output voltage/frequency, battery voltage/capacity |
| Noise (dB) |
45~55 |
| Environment |
Temperature -5oC~+40oC, Humidity 95% No coagulation (- 40oC OPTIONAL) |
| Weight(Kg) |
25Kg |
17Kg |
46Kg/52Kg |
30Kg |
57Kg |
36Kg |
| Body Dimension |
470x170
x320 |
470x170
x260 |
483x170
x380 |
483x170
x260 |
533x170
x555 |
533x170
x435 |